Ion concentration meterのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Ion concentration meter - メーカー・企業と製品の一覧

Ion concentration meterの製品一覧

1~9 件を表示 / 全 9 件

表示件数

[Case Study] ATI Fluoride Ion Meter [Free Giveaway]

We are currently offering free listings of case studies for ATI fluoride ion meters. This includes measuring fluoride ion concentration in wastewater and monitoring fluoride concentration in drinking water.

The ATI fluoride ion meter continuously measures the concentration of fluoride ions in wastewater. It is used for controlling the wastewater treatment processes in semiconductor factories and for monitoring the final effluent.

  • 1359.gif
  • Water quality testing

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Instran Online Fluoride Ion Concentration Meter

Fluorine concentration can be measured with a wide range and high precision from a minimum of 0 to 0.5 ppm to a maximum of 0 to 100 ppm!

We adopt the SKA method to calculate concentration based on the difference in concentration between a standard solution of known concentration and the sample. By comparing the potential differences, we can minimize the impact of the measurement environment on the results. During measurement, reagents are used to adjust the pH. This removes interference from ions other than fluoride, enabling high-precision measurement of fluoride concentration.

  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

ATI Fluoride Ion Concentration Meter "Q46F Model"

By supplying a certain sample of water, it automatically controls the flow rate, pressure, and pH to measure fluoride ions!

The "Q46F model" can be used for continuous measurement of fluoride ions in wastewater, effluent, and drinking water. It employs a fluoride ion selective electrode (ISE) and can measure fluoride ions from 0.1 PPM to a maximum of 1000 PPM. With its simple structure, it allows for low-cost continuous measurement of fluoride ions. *For more details, please refer to the PDF document or feel free to contact us.

  • 1360.gif
  • Other physicochemical equipment
  • Other process controls
  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Instran Online Chloride Ion Concentration Meter

It is possible to measure chlorine ion concentration with a wide range and high precision from a minimum of 0 to 5 ppm to a maximum of 0 to 500 ppm!

The SKA method is employed to calculate concentration based on the difference in concentrations between a standard solution of known concentration and the sample. By comparing the potential differences, the influence of the measurement environment on the results can be minimized. There are several interfering substances in the measurement of chloride ions, but this method allows for their easy removal.

  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Online fluoride ion concentration meter

Online fluoride ion concentration meter

The ion electrode method using TISAB for preprocessing can automatically switch to measure fluoride ion concentrations in four systems (online). The measurement range is 0-2000 ppm. The consumption of TISAB reagent is approximately 0.7 ml per measurement, allowing for maximum reduction in reagent costs. With 1 liter of reagent, about 1500 measurements can be performed. It also supports digital communication (Profibus) as an option. It can also accommodate an automatic calibration function.

  • Other process controls
  • Analytical Equipment and Devices
  • Wastewater/wastewater treatment equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Instran Online Copper Ion Concentration Meter

Continuous measurement of copper ion concentration in water is possible!

Method - Colorimetric Analysis After adding the sample to the measurement cell, several reagents are added to adjust the conditions of the solution (such as pH and oxidation state). Subsequently, a blank measurement is performed to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce a color that is measured at the appropriate wavelength. The photometer used allows for highly accurate measurement results. This method is based on the reduction of copper(II) to copper(I) in acidic solutions. The neocuproine reagent specifically reacts with cuprous ions (Cu⁺). If present, iron can also be reduced to iron(II) (Fe²⁺) and may react with neocuproine. This method is specific to copper, and the cuprous-neocuproine complex has a clear and relatively strong absorbance, allowing for the measurement of low concentrations of copper at the ppb level. The influence of iron can be removed with additional reagents.

  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Instran Online Low Concentration Iron Ion Concentration Meter

Continuous measurement of low concentrations of iron ions in water is possible!

Method - Colorimetric Analysis After the sample is introduced into the measurement cell, several reagents are added to adjust the solution conditions (such as pH and the valence of elements). Subsequently, a blank measurement is conducted to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce a color that is measured at the appropriate wavelength. Depending on the photometer used, the results are obtained with very high precision. Trivalent iron (Fe³⁺) is reduced to divalent iron (Fe²⁺) by hydroxylamine hydrochloride. The divalent iron ions react with ferrozine in a buffer solution adjusted to a pH range of 5 to 7, forming a pink complex. This method allows for the measurement of very low concentrations of iron. The reagents used are stable. If it is necessary to measure total iron, the stirring time can be extended to ensure that the iron is completely dissolved in an acidic medium.

  • Other measurement, recording and measuring instruments

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Ion concentration meter Ionometer

Analysis device manufactured by the Belgian company Brannlube.

With the online monitor using potential difference measurement, up to six measurement points can be measured.

  • Analytical Equipment and Devices
  • Other measurement, recording and measuring instruments
  • Water quality testing

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Instran Online High Concentration Iron Ion Concentration Meter

Continuous measurement of iron ion concentration in water is possible!

Method - Colorimetric Analysis After introducing the sample into the measurement cell, several reagents are added to adjust the conditions of the solution (such as pH and the valence of elements). Subsequently, a blank measurement is performed to correct for the effects of temperature and turbidity. Then, the final reagent is added, which reacts with the solution to produce a color that is measured at the appropriate wavelength. Depending on the photometer used, the results are obtained with very high precision. Trivalent iron ions (Fe³⁺) are reduced to divalent iron (Fe²⁺) by hydroxylamine hydrochloride. Divalent iron ions react with 1:10-phenanthroline in a solution adjusted to a pH range of 5 to 7 to form a pink complex. This method allows for the measurement of relatively high concentrations of iron without excessive absorbance. The reagents used are stable. If it is necessary to measure total iron, the stirring time can be extended to ensure that the iron completely dissolves in the acidic solution.

  • Other measurement, recording and measuring instruments